banner

How to install and adjust the ultrasonic sonotrode

  • 2021-07-01
How to install and adjust the ultrasonic mold? We will all encounter it when replacing the ultrasonic mold. The editor will share some knowledge of ultrasonic welding with you below.

1. Install the mold

1. First wipe the transducer (CONE), mold (HORN) and the connecting screw with alcohol or gasoline, and then smear the connecting screw, transducer, and mold with a thin layer of yellow grease before welding. The head screw is locked on the welding head. Note: If the joint surface of the transducer and the mold is damaged, the transmission efficiency of vibration will decrease, so care should be taken to maintain it.

2. Tighten the 4 welding head level adjustment screws to fix the transducer in the middle of its rotation range.

3. Screw the mold into the transducer by hand until it can't rotate.

4. Tighten the mold with a mold lock wrench (about 300Kg/cm torque). At this time, pay special attention to not allowing the transducer to rotate to prevent the tip from twisting. (If rotation is found, the 4 horizontal adjustment screws should be tightened more).

Two, mold adjustment

1. Adjustment preparation:
(1) Turn on the air pressure source and adjust the pressure to 2kg/C㎡;
(2) Turn on the main power switch on the vibration box, and the power indicator light is on.

2. Adjustment of mold direction:
Loosen the 4 horizontal adjustment screws, align the orientation of the mold with the work object, and then press the body lift switch to press the welding head against the work object.

3. Mold level adjustment:
Gently pat around the mold to make the mold match the work object, and fix 4 horizontal adjustment screws on average.

4. Adjust the mold height position:
If the welding of the work requires preparation for the height, adjust the lowest point fine-tuning screw to the most appropriate position of the lifting cylinder after welding.

5. Welding preparation of ultrasonic plastic welding machine:
According to the condition of the work, set the number of output stages in the appropriate position. (The life should be maintained from the low stage count) Press the sonic check switch again, and turn the sonic adjustment screw, so that the indication of the amplitude meter is at the lowest scale. Note: Press the sonic check switch and press it for three seconds to stop the one-second intermittent mode to maintain the life of the vibrator.

© Copyright: 2024 Hangzhou Altrasonic Technology Co.,Ltd All Rights Reserved

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.